Hepworth Heating Ltd.,
Nottingham Road, Belper, Derbyshire. DE56 1JT
General/Sales enquiries:
Tel: (01773) 824141 Fax: (01773) 820569
One Contact Local Service
Customer Services:
Tel: (01773) 828100
Fax: (01773) 828070
221758A.10.00
All replacement parts
All labour charges
All call-out charges
Guarantee Registration
Hideaway 120
Open Flue Boiler
This is a Cat I
2H
Appliance
BS 6332
BS 5258
Reference in these instructions to British Standards and Statutory
Regulations/Requirements apply only to the United Kingdom.
For Ireland the rules in force must be used.
To be left with the user
1369
Instructions for Use
Installation and Servicing
G.C. No. 41 313 29
REGISTER YOUR GLOW-WORM APPLIANCE
FOR 1ST YEAR GUARANTEE PROTECTION
CALL 0208 247 9857
Thank you for installing a new Glow-worm appliance in your home.
Glow-worm appliances' are manufactured to the very highest standard so we are pleased
to offer our customers' a Comprehensive First Year Guarantee.
In the center pages are to be found your Guarantee Registration Card, which we recommend you complete and
return as soon as possible.
If this card is missing you can obtain a copy or record your registration by telephoning the Heatcall Customer
Service number 01773 828100.
Our Guarantee gives you peace of mind plus valuable protection against breakdown by covering the cost of:
The instructions consist of three parts, User, Installation and Servicing Instructions, which includes the Guarantee Registration
Card. The instructions are an integral part of the appliance and must, to comply with the current issue of the Gas Safety
(Installation and Use) Regulations, be handed to the user on completion of the installation.
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - Installation and Servicing

Hepworth Heating Ltd.,Nottingham Road, Belper, Derbyshire. DE56 1JTGeneral/Sales enquiries:Tel: (01773) 824141 Fax: (01773) 820569One Contact Local S

Seite 2 - Important Information

10221758AFit the distributor tube, see diagram 4.2 or 4.4 for location, seediagram 4.3 for alignment. Fit appropriate fittings and plugs intothe boil

Seite 3

11 221758ASIDE CASINGS FITTINGDiagram 5.21018LOCATINGLUG ANDSLOTNo. 8SCREW (2)No. 8SCREW (2)CASINGBRACKETCASINGBRACKETBOILERPLINTH5 Casing Location

Seite 4

12221758AAPAPPPCBCBCBCB230(9)25(1)230(9)230(9)6.1 Control Box Cable ConnectionRemove the screw and cover from the mains inlet connector,see diagram 6.

Seite 5 - 1 General

13 221758A7 CommissioningPlease ensure the “Benchmark” logbook is completed and leftwith the user.7.1 PreliminariesThe whole of the system, with the

Seite 6

14221758A7 CommissioningHideaway 120 - 4.4 to 5.2m3/h 125 to 148ft3/hThese figures are for guidance only.Stick the self adhesive arrow indicator, fro

Seite 7 - 2 Water Systems

15 221758A8 ServicingServicing must be carried out by a competent person.Before starting any servicing, turn off the gas and electricalsupply to the

Seite 8 - 3 Flue and Ventilation

16221758A8 Servicing8.3 Burners and InjectorsFollow instructions to remove the cover, burner and controlsassembly as described in Section 8.2.Remove

Seite 9

17 221758A9 Replacement of PartsBefore removing or replacing any parts turn off the gas andelectrical supplies to the boiler.Always test for gas so

Seite 10 - 4 Installation

18221758A9.7 Boiler ThermostatFollow the relevant instructions in Section 8.1.Remove the mains inlet connector by pulling downwards, seediagram 8.1.Re

Seite 11 - 5 Casing Location / Fitting

19 221758A9 Replacement of Parts9.8 Piezo UnitPull door forward at the top to disengage the studs and lift torelease from slots, see diagram 7.3.Re

Seite 12 - 6 Electrical Wiring

2221758ANotes and General InformationPlease read these instructions and follow them carefully for thesafe and economical use of your boiler.The boiler

Seite 13 - 7 Commissioning

20221758A9 Replacement of PartsPHIAL ASSEMBLY REMOVALDiagram 9.8LOCATION STUDSECURING NUT6298PHIALPHIAL ASSEMBLYFUNCTIONAL FLOW WIRINGDiagram 10.11

Seite 14

21 221758A10 Fault Finding - ElectricalDiagram 10.2ELECTRICAL FAULT FINDINGFaulty gas valve.Replace.Turn boiler thermostat to "O'.Does mai

Seite 15 - 8 Servicing

22221758ARe-connect boiler flue blockage safety device to points A and B. Disconnect thermocouple at connection point D of the gas valve. Test conti

Seite 16 - 8 Servicing

23 221758A10 Fault Finding - PilotDiagram 10.6PILOT / IGNITION FAULT FINDING0905ASTART HERECheck gas line - open all cocks,rectify any blockages, pu

Seite 17 - 9 Replacement of Parts

24221758A11 Spare Parts1 203323 Gas control valve 394 3482 205746 Injector - 120 x23 203414 Pilot burner 312 2464 203508 Injector - pilot 395 6745 9

Seite 18

3 221758AWarningMake sure that nothing obstructs the rear side grilles orclearances. See diagram 1.2 and 1.3 for minimum clearances.Boilers Installed

Seite 19

4221758ASafety DeviceThis appliance is fitted with a flue blockage safety device whichwill shut down the appliance in the event of abnormal fluecondit

Seite 20

5 221758ADiagram 1.1GENERAL DIMENSIONS - given in millimetres (Approx. inches)RANGE RATINGHIDEAWAY 120NOMINALkWHEAT INPUT(GROSS)Btu/h37.10 40.5 43.96

Seite 21 - ELECTRICAL FAULT FINDING

6221758A1 General1.4 B.S.I. CertificationThis boiler is certificated by B.S.I. for safety and performance.It is, therefore, important that no alterat

Seite 22

7 221758A1.00.80.60.40.20302010001020 3040 50FLOW RATE (LITRES/MINUTE)WATER PRESSURE LOSS(metre HEAD OF WATER)WATER PRESSURE LOSS(INCHES HEAD OF WATER

Seite 23 - 10 Fault Finding - Pilot

8221758AImportant NoteThe boiler is fitted with a Flue Blockage Safety Device, whichwill shut down the boiler if there is an unacceptable spillage ofp

Seite 24 - 11 Spare Parts

9 221758A4 InstallationCASING BRACKETS FITTINGDiagram 4.11000CAPTIVENUTCASINGBRACKETCAPTIVENUTCASINGBRACKETNo.8 SCREW (8)Before fitting the boiler ma

Kommentare zu diesen Handbüchern